PACIFIC ELECTRONICS - DEALER "SANWA ELECT.MEASURING INSTRUMENTS"

Enquiry 0
Cart 0

Test & Measuring

SANWA PM3

  • $50.00

Digital Multimeter

8.5mm thick body with multi-function

  • 4000 counts
  • Best accuracy 0.7%
  • Auto power off(15min.)(cancelable)

PM3-icon-1


Product Catalog
Share

This product is temporarily out of stock. You may opt-in our waiting list and we'll notify you once the product is restocked.

Models: Sanwa PM3 Pocket-Sized Digital Insulation Tester

Sanwa PM3

 

Included Accessories:

  • C-PM3 Carrying Case

PM3

Measuring range

Best accuracy

Resolution

Input impedance

DCV

400m/4/40/400/500V

±(0.7%+3)

0.1mV

10M100MΩ

ACV

4/40/400/500V

±(2.3%+5)

0.001V

10M11MΩ

Resistance

400/4k/40k/400k/4M/40MΩ

±(2.0%+5)

0.1Ω

 

Capacitance

5n/50n/500n/5μ/50μ/200μF

±(5.0%+10)

0.001nF

Frequency

9.999/99.99/999.9/9.999k/60.00kHz

±(0.7%+5)

0.001Hz

Duty cycle

0.199%

Continuity

Buzzer sounds at less than 10Ω120Ω Open voltage:Approx.0.4V

Diode test

Open voltage:approx.1.5V

 

 

Display

numeral display 4000

Sampling rate

3 times/sec.

Bandwidth

40400Hz

Bettry

Coin type lithium battery CR2032(3V)x1

Bettery life

Approx.150h at DCV

Size/Mass

H108×W56×D11.5mm/Approx.50g

Test lead length/Pin tip

Length: approx.0.5m/18mm

Safety

IEC61010 CAT.DC/AC500V

Frequency -
Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
 
Capacitor -
Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
 
Duty cycle -
The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
 
Continuity buzzer -
The buzzer sounds when the measuring object is electrically conducting.
 
Auto power off -
Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
 
Data hold -
A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
 
Measurement of relative value -
A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
 
Low power ohm (Ω) -
Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.

Product Catalogue

Instruction Manual