Digital
HIOKI DT4253
- $339.00
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4253 is a digital multimeter designed specifically for HVAC testing, with ±0.5% DC V accuracy, temperature and clamp sensor testing, and wide 40 Hz to 1 kHz bandwidth.
CAT IV 600 V, CAT III 1000 V
Key Features:
- Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Dual display lets you check voltage and frequency simultaneously
This product is temporarily out of stock. You may opt-in our waiting list and we'll notify you once the product is restocked.
Models: DT4253 Digital Multimeter
HIOKI DT4253
Included Accessories:
- Test lead L9207-10 ×1
- Holster ×1
- Instruction manual ×1
- LR03 alkaline battery ×4
Basic specifications
Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range | 600.0 mV to 1000 V |
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz |
| AUTO AC/DCV | Yes |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt. |
| DC Current range | 60.00 μA to 60.00 mA, 4 ranges, |
| From 4 to 20mA Percentage conversion display | Yes |
| AC Current range | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| Temperature | K: -40.0 to 400.0 °C , Add the Temperature probe accuracy to basic accuracy: ±0.5 % rdg. ±2 °C |
| Voltage detection | N/A |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
| Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), |
| Continuity check | Continuity threshold [ON]: 25 Ω or less , |
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, |
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option), 4-20 mA percentage conversion |
| Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) |
| Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
| Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, |
| Included accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |