PACIFIC ELECTRONICS - DEALER "SANWA ELECT.MEASURING INSTRUMENTS"

Enquiry 0
Cart 0

Test & Measuring

SANWA CD800a

  • $60.00

Digital Multimeter

Tough body cover

  • 4000 counts
  • Best accuracy 0.7%
  • Auto power off(30min.)(cancelable)
  • Low power ohm(input voltage 0.4V)at continuity range
  • Solid & portective body cover that can also be used as a tilt stand
  • Chip resister holder behind the body cover

CD800a-icon


Product Catalog
Share

This product is temporarily out of stock. You may opt-in our waiting list and we'll notify you once the product is restocked.

Models: Sanwa CD800a Digital Multimeter

Sanwa CD800a

Included Accessories:

  • Hand Strap
  • Instruction Manual

CD800a

Measuring range

Best accuracy

Resolution

Input impedance

DCV

400m/4/40/400/600V

±(0.7%+3)

0.1mV

10M100MΩ

ACV

4/40/400/600V

±(1.6%+5)

0.001V

10M11MΩ

DCA

40m/400mA

±(2.2%+5)

0.01mA

 

ACA

40m/400mA

±(2.8%+5)

0.01mA

Resistance

400/4k/40k/400k/4M/40MΩ

±(1.2%+5)

0.1Ω

Capacitance

50n/500n/5μ/50μ/100μF

±(5%+10)

0.01nF

Frequency

5Hz100kHz

±0.5%+3)

Duty cycle

20%80%

±0.5%+5)

Continuity

Buzzer sounds at between 10Ω and 120Ω Open voltage:Approx.0.4V

Diode test

Open voltage:approx.1.5V

 

 

Display

numeral display 4000

Sampling rate

3 times/sec.

Bandwidth

40Hz400Hz

Fuse

0.5A/250V 1.5kA Φ5×20 Ceramic

Battery

R6P(1.5V)x2

Battery life

Approx.500h (manganese battery) at DCV range

Size/Mass

H176×W104×D46mm/Approx.340g

Test lead length/Pin tip

Length: approx. 0.7m/19mm

Frequency -
Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
 
Capacitor -
Capacitor capacity (electrostatic capacity) is measured and expressed in the unit of F (farad), μF, etc.
 
Duty cycle -
The duty cycle of repeating waveform is indicated on a percentage basis (%). It can be used for the analysis of control signals.
 
Continuity buzzer -
The buzzer sounds when the measuring object is electrically conducting.
 
Auto power off -
Power is automatically turned off when a certain time has elapsed after power-up. Some models have a function to cancel this function.
 
Data hold -
A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
 
Range hold -
The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
 
Measurement of relative value -
A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
 
Low power ohm (Ω) -
Resistance is measured by applying voltage of approximately 0.4V or less on a measuring object. It is characterized by the fact that the semiconductor does not conduct at approximately 0.4V or less even in forward direction.

Product Catalogue

Instruction Manual