PACIFIC ELECTRONICS – FLUKE DISTRIBUTOR SINCE 1958

Enquiry 0
Cart 0

Test & Measuring

FLUKE 115

  • $388.00

Fluke 115 Field Technicians Digital Multimeter

Key features

  • Compact True-rms digital multimeter for field service
  • Includes: meter, holster, 4 mm silicone test lead set
  • Easy one-handed operation of the meter
  • Min/Max/Average to record signal fluctuations

Share

This product is temporarily out of stock. You may opt-in our waiting list and we'll notify you once the product is restocked.

Models: Fluke 115 Field Technicians Digital Multimeter

Fluke 115 Digital Multimeter

Includes:

  • Holster
  • Installed 9V battery
  • 4 mm silicone test lead set
  • User manual

Product overview: Fluke 115 Field Technicians Digital Multimeter

Compact true-rms meter for field service technicians

The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.

The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:

  • AC and DC voltage to 600V,
  • AC and DC current to 10 A (20 A overload for 30-seconds max).

What's in the box:

  • Digital multimeter
  • Holster
  • Installed 9V battery
  • 4 mm silicone test lead set
  • Quick Reference Guide

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

± ([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V

Accuracy

± ([% of reading] + [counts]): 0.5% + 2

AC millivolts1 True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts1 True RMS

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS
(45 Hz to 500Hz)

Range/resolution

6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy

1.5% + 3
20 A overload for 30-seconds max

DC amps

Range/resolution

6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy

1.0% + 3
20 A overload for 30-seconds max

Hz (V or A input)2

Range/resolution

99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40 to 752 / 0.2.

General Specifications

Maximum voltage between any terminal and earth ground

600 V

Safety

IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10 to + 50

Storage temperature

-40 to + 60

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Warranty